The setup is designed to
study the discharge through different orifice & mouthpiece. Set up
consists of an adjustable
head constant level tank, supply tank, measuring tank and pump for closed loop
water circulation. The constant level tank is fitted with arrangement for
creating jet using different interchangeable orifice and mouthpiece. A
hook/pointer gauge for measuring xy coordinates of jet is also fitted. The flow rate of water is measured using
measuring tank and stop watch provided.
EXPERIMENTS:
Ø To determine the coefficient of discharge of different
Orifice and mouthpiece
FEATURES:
Ø Acrylic test section
Ø Closed loop water circulation
Ø Compact & stand-alone set up
Ø Stainless Steel tanks and wetted parts
Ø Superb Painted structure
Ø Simple to operate & maintain
UTILITIES REQUIRED:
Ø Electric supply 0.5 kW, 220V AC, Single Phase
Ø Water supply Tap water connection ½” BSP Distilled water @ 60
liters (optional)
Ø Floor Area with Drain facility
TECHNICAL DETAILS:
|
Product
|
Orifice & Mouthpiece Apparatus
|
|
Orifice
|
Set of 2, Material Acrylic (Diameter 10mm and 15 mm)
|
|
Set of Mouthpieces
|
Set of 3, Material Acrylic (Dia. 10mm with L/D = 1, 2.5
& 4 )
|
|
Constant level tank
|
Capacity 25 Liters. MOC SS
|
|
Supply Tank
|
Capacity 50 Liters. MOC SS
|
|
Measuring tank
|
Capacity 25 Ltrs. MOC SS fitted with Piezometer Tube &
scale
|
|
Hook/Pointer Gauge
|
To measure XY coordinates of Jet
|
|
Pump
|
FHP capacity make Tullu / Crompton Greaves
|
|
Piping
|
GI / PVC
|
|
Stop Watch
|
Electronic
|
|